- Equipment cache: add freshness gate so only 1 Oracle query per 5-min cycle
  across 4 gunicorn workers; sync worker waits before first refresh
- Portal: add frame-busting to prevent recursive iframe nesting
- Hold Overview: remove redundant TreeMap, add Product & Future Hold Comment
  columns to LotTable
- Hold History: switch list.sql JOIN from DW_MES_LOT_V (WIP snapshot) to
  DW_MES_CONTAINER (historical master) for reliable Product data; add
  Future Hold Comment column; fix comment truncation with hover tooltip
- Page status: reorganize drawer groupings

Co-Authored-By: Claude Opus 4.6 <noreply@anthropic.com>
2026-02-11 09:01:02 +08:00

2.1 KiB

equipment-sync-dedup Specification

Purpose

Ensure multi-worker equipment status cache sync performs at most one Oracle query per sync cycle, preventing redundant identical queries across gunicorn workers.

Requirements

Requirement: Equipment Sync Refresh SHALL Skip Redundant Oracle Queries Within Same Cycle

When multiple workers attempt to refresh the equipment status cache within the same sync cycle, only the first successful refresh SHALL query Oracle. Subsequent workers that acquire the distributed lock MUST check the freshness of the existing cache and skip the Oracle query if the cache was recently updated.

Scenario: Another worker already refreshed within current cycle

  • WHEN a worker acquires the distributed lock and the equipment_status:meta:updated timestamp is less than half the sync interval old
  • THEN the worker MUST release the lock without querying Oracle and return False

Scenario: No recent refresh exists

  • WHEN a worker acquires the distributed lock and the equipment_status:meta:updated timestamp is older than half the sync interval (or missing)
  • THEN the worker MUST proceed with the full Oracle query and cache update

Scenario: Force refresh bypasses freshness gate

  • WHEN refresh_equipment_status_cache(force=True) is called
  • THEN the freshness gate MUST be skipped and the Oracle query MUST proceed regardless of meta:updated age

Requirement: Sync Worker SHALL Not Duplicate Init Refresh

The background sync worker thread MUST wait for one full sync interval before its first refresh attempt, since init_realtime_equipment_cache() already performs an initial refresh at startup.

Scenario: Sync worker startup after init

  • WHEN the sync worker thread starts after init_realtime_equipment_cache() completes the initial refresh
  • THEN the worker MUST wait for the configured interval before attempting its first refresh

Scenario: Stop signal during wait

  • WHEN a stop signal is received while the sync worker is waiting
  • THEN the worker MUST exit without performing a refresh